Title
Analiza faktora koji utiču na neupotrebljivost transfuzioloških jedinica
Creator
Radonjić, Dragan, 1959-
CONOR:
28277607
Copyright date
2022
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Inventory ID
D-3550
Theses Type
Doktorska disertacija
description
Datum odbrane: 12.10.2022.
Other responsibilities
Academic Expertise
Medicinske nauke
University
Univerzitet u Kragujevcu
Faculty
Fakultet medicinskih nauka
Alternative title
Analysis of factors affecting inapplicability of transfusion units
Publisher
[D. B. Radonjić]
Format
120 listova
Abstract (sr)
Uvod: Neupotrebljiva transfuziološka jedinica predstavlja onu jedinicu krvi ili
preparat krvi dobiven iz krvi koji u traženom momentu ne zadovoljava evropske
standarde kvaliteta o primeni bezbedne krvi i ne može se primeniti pacijentu kome
je ona potrebna. Postoji više faktora koji utiču i doprinose neupotrebljivosti
transfuzioloških jedinica: (1) neadekvatna edukacija i selekcija davalaca krvi, (2)
nepravilan način uzimanja i obrade jedinica krvi, (3) nepravilan način
skladištenja i čuvanja transfuzioloških jedinica, (4) jedinice krvi pozitivne na
markere krvlju prenosivih bolesti, i (5) nepravilan način pripreme i primene
pojedinih jedinica krvi.
Cilj: Utvrditi faktore koji su povezani sa neupotrebljivošću jedinica krvi i
derivata krvi u transfuziološkoj praksi.
Materijal i metode: Studija je dizajnirana kao opservaciono istraživanje po tipu
studije preseka, gde su analizirane sve prikupljene jedinice krvi u
transfuziološkoj službi u određenom vremenskom periodu, kako bi se otkrile
jedinice krvi i njenih derivata koje su neupotrebljive, kao i razlozi zbog kojih su
postale neupotrebljive. Kontrolnu grupu čine jedinice krvi i derivata krvi koje su
po evropskim standardima kvaliteta bile upotrebljive i čine bezbednu ili sigurnu
krv. Studija je retrospektivna i sprovedena je u organizacionoj jedinici transfuzije
krvi u Baru u periodu od dve godine - počevši od 1. jula 2016. godine do 1. jula
2018. godine.
Rezultati: Značajan procenat analiziranih jedinica krvi koje su bile uzete od
davalaca nije bio upotrebljiv (11,0%), pri čemu su najčešći razlozi bili: istekao
rok trajanja (36,9%), hilozna hrv (26,8%), nedovoljan volumen krvi (14,8%), hemoliza
(10,6%), oštećenje pakovanja pri procesu uzimanja, obrade i pripreme krvi (8,1%), krv
pozitivna na transmisivne bolesti (3,4%), krv sumnjiva na transmisivne bolesti
(8,7%) i prisustvo ugrušaka u eritromasi (0,6%). Procenat neupotrebljive krvi je
veći kada se krv donira tokom zime, nego tokom drugih godišnjih doba. Uzimanje krvi
od donatora van zdravstvene ustanove, a posebno u školama, je povezano sa većom
učestalošću neupotrebljivih transfuzioloških jedinica. Kod uzimanja krvi od
donatora sa komorbiditetima učestalost neupotrebljivih transfuzioloških
jedinica je značajno veća nego kada se krv uzima od donatora bez komorbiditeta.
Zaključak: Samo bezbedna krv predstavlja lek koji je kvalitetan, efikasan i siguran
u lečenju bolesnika kojima je ona potrebna. Poštovanje evropskih standarda o
bezbednoj krvi i uvođenje za to potrebnih preventivnih mjera, posebno kada postoje
faktori rizika, značajno smanjuje broj neupotrebljivih transfuzioloških jedinica
što doprinosi bržem i kvalitetnijem lečenju obolelih osoba.
Abstract (en)
Introduction: An unusable transfusion unit is a unit of blood or blood preparation obtained
from blood that does not meet European quality standards for the use of safe blood and
cannot be administered to a patient who needs it. There are several factors that affect and
contribute to the unusability of transfusion units and they are: (1) inadequate education and
selection of blood donors, (2) improper way of taking and processing blood units, (3)
improper way of storing and storing transfusion units, (4) units of blood positive for markers
of blood-borne diseases, and (5) improper preparation and administration of individual blood
units.
Аim: To determine the factors related to the unusability of blood units and blood derivatives
in transfusion practice.
Material and methods: The study is designed as an observational, cross-sectional study,
which analyzes all collected blood units in the transfusion service in a certain period of time,
to identify units of blood and its derivatives that are unusable, as well as the reasons why
they became unusable. The control group consists of units of blood and blood derivatives that
were usable according to European quality standards and constitute safe or secure blood. The
study is retrospective and was conducted in the organizational unit of blood transfusion in
Bar for a period of two years - starting from July 1, 2016 to July 1, 2018.
Results: A significant percentage of analyzed blood units taken from donors were not usable
(11.0%), with the most common reasons being: expired (36.9%), chylous blood (26.8%),
insufficient blood volume (14.8%), hemolysis (10.6%), damage to the packaging during the
process of taking, processing and preparation of blood (8.1%), blood positive for
transmissible diseases (3.4%), blood suspected of transmissible diseases (8.7%) and the
presence of clots in erythromass (0.6%). The percentage of unusable blood was higher when
blood was donated during the winter than during other seasons. Blood sampling from donors
outside the health facility, and especially in schools, was associated with a higher frequency
of unusable transfusion units. When taking blood from donors with comorbidities, the
frequency of unusable transfusion units was significantly higher than when taking blood from
donors without comorbidities.
Conclusion: Only safe blood is a drug that is of high quality, effective and safe in the
treatment of patients who need it. Adherence to European standards on safe blood and the
introduction of the necessary preventive measures, especially when there are risk factors,
significantly reduces the number of unusable transfusion units, which contributes to faster
and better treatment of patients.
Authors Key words
Neupotrebljive transfuziološke jedinice, bezbedna krv, preventivne
mere, Evropski standardi kvaliteta
Authors Key words
Unusable transfusion units, safe blood, preventive measures, European quality
standards
Classification
615.38(043.3)
Type
Tekst
Abstract (sr)
Uvod: Neupotrebljiva transfuziološka jedinica predstavlja onu jedinicu krvi ili
preparat krvi dobiven iz krvi koji u traženom momentu ne zadovoljava evropske
standarde kvaliteta o primeni bezbedne krvi i ne može se primeniti pacijentu kome
je ona potrebna. Postoji više faktora koji utiču i doprinose neupotrebljivosti
transfuzioloških jedinica: (1) neadekvatna edukacija i selekcija davalaca krvi, (2)
nepravilan način uzimanja i obrade jedinica krvi, (3) nepravilan način
skladištenja i čuvanja transfuzioloških jedinica, (4) jedinice krvi pozitivne na
markere krvlju prenosivih bolesti, i (5) nepravilan način pripreme i primene
pojedinih jedinica krvi.
Cilj: Utvrditi faktore koji su povezani sa neupotrebljivošću jedinica krvi i
derivata krvi u transfuziološkoj praksi.
Materijal i metode: Studija je dizajnirana kao opservaciono istraživanje po tipu
studije preseka, gde su analizirane sve prikupljene jedinice krvi u
transfuziološkoj službi u određenom vremenskom periodu, kako bi se otkrile
jedinice krvi i njenih derivata koje su neupotrebljive, kao i razlozi zbog kojih su
postale neupotrebljive. Kontrolnu grupu čine jedinice krvi i derivata krvi koje su
po evropskim standardima kvaliteta bile upotrebljive i čine bezbednu ili sigurnu
krv. Studija je retrospektivna i sprovedena je u organizacionoj jedinici transfuzije
krvi u Baru u periodu od dve godine - počevši od 1. jula 2016. godine do 1. jula
2018. godine.
Rezultati: Značajan procenat analiziranih jedinica krvi koje su bile uzete od
davalaca nije bio upotrebljiv (11,0%), pri čemu su najčešći razlozi bili: istekao
rok trajanja (36,9%), hilozna hrv (26,8%), nedovoljan volumen krvi (14,8%), hemoliza
(10,6%), oštećenje pakovanja pri procesu uzimanja, obrade i pripreme krvi (8,1%), krv
pozitivna na transmisivne bolesti (3,4%), krv sumnjiva na transmisivne bolesti
(8,7%) i prisustvo ugrušaka u eritromasi (0,6%). Procenat neupotrebljive krvi je
veći kada se krv donira tokom zime, nego tokom drugih godišnjih doba. Uzimanje krvi
od donatora van zdravstvene ustanove, a posebno u školama, je povezano sa većom
učestalošću neupotrebljivih transfuzioloških jedinica. Kod uzimanja krvi od
donatora sa komorbiditetima učestalost neupotrebljivih transfuzioloških
jedinica je značajno veća nego kada se krv uzima od donatora bez komorbiditeta.
Zaključak: Samo bezbedna krv predstavlja lek koji je kvalitetan, efikasan i siguran
u lečenju bolesnika kojima je ona potrebna. Poštovanje evropskih standarda o
bezbednoj krvi i uvođenje za to potrebnih preventivnih mjera, posebno kada postoje
faktori rizika, značajno smanjuje broj neupotrebljivih transfuzioloških jedinica
što doprinosi bržem i kvalitetnijem lečenju obolelih osoba.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.