Title
Značaj korelacije analize gustine kosti i primarne stabilnosti kod izbora dizajna dentalnih implantata
Creator
Mikić, Mirko, 1987-, 65029129
Copyright date
2020
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Inventory ID
D-3399
Theses Type
Doktorska disertacija
description
Datum odbrane: 29.12.2020.
Other responsibilities
mentor
Vlahović, Zoran, 1971-, 58711305
predsednik komisije
Bubalo, Marija, 1973-, 1646951
član komisije
Lazić, Zoran, 1963-, 5197415
član komisije
Vasović, Miroslav, 1982-, 24921191
Academic Expertise
Medicinske nauke
University
Univerzitet u Kragujevcu
Faculty
Fakultet medicinskih nauka
Alternative title
Significance of the correlation of bone density analysis and primary stability in the choice of dental implant design
Format
112 listova
Abstract (sr)
UVOD: Oseointegracija predstavlja preduslov uspjeha implantatne terapije. Kvalitet i kvantitet kosti, dizajn implantata i hirurška tehnika ugradnje, su najznačajniji faktori koji utiču na primarnu stabilnost implantata koja predstavlja preduslov oseointegracije.
METODOLOGIJA: U razrešenju postavljenih ciljeva sprovedena je eksperimentalna
studija na materijalu životinjskog porijekla: goveđem femuru i svinjskim rebrima i klinička prospektivna eksperimantalna studija na ljudima, sa nedostatkom jednog zuba u
bočnoj regiji indikovanih za ugradnju implantata. U ovoj studiji su korišćene dvije
vrste imlantata: samourezujući (Bredent-Narrow SKY) i neurezujući (Nobel Replace –
Conical Connection) istih dimenzija.
REZULTATI: Rezultati eksperimentalne studije su pokazali statistički značajnu
povezanost gustine kosti izražene u HU jedinicama i primarne stabilnosti
samourezujućih i neurezujućih dentalnih implantata izražene u ISQ jedinicama u
kostima goveđeg femura i samourezujućih implantata i kostima svinjskog rebra. Nije
bilo statistički značajne povezanosti neurezujućih dentalnih implantata u kostima
svinjskog rebra. Samourezujući i neurezujući implantati nijesu pokazali statistički
značajnost u primarnoj stabilnosti u kostima različitog kvaliteta. U kliničkoj studiji
je dokazano da postoji statistički značajna jaka pozitivna povezanost između gustine
kosti izražene u HU jedinicama izmjerene u softveru CBCT aparata i primarne
stabilnosti dentalnih implantata izraženih u ISQ jedinicama;
ZAKLjUČAK: Analizom gustine koštanog tkiva CBCT sniimka u softveru aparata
izraženom u HU jedinicama može se predvidjeti stepen primarne stabilnosti
samourezujućih i neurezujućih dentalnih implantata u kostima gustine D1, D2 i
samourezujućih dentalnih imlantata u kostima slabijeg kvaliteta gustine D4. Stepen
primarne stabilnosti neurezujućih dentalnih implantata u kostima slabijeg kvaliteta
D4 ne može se predvidjeti. Više vrijednosti HU povezane su sa višim vrednostima ISQ.
Abstract (en)
INTRODUCTION: Osseointegration stands as a prerequisite for the success of implant therapy. Bone quality and quantity, implant design, and surgical technique represent the most important factors influencing the primary stability of the implant, which is a prerequisite for osseointegration.
METHODOLOGY: In order to solve the set objectives, an experimental study was conducted on a material of animal origin: bovine femur and pig ribs and a clinical prospective experimental study on humans, lacking one tooth in the lateral region indicated for implant placement. Two
types of implants were used in this study: self-tapping (Bredent-Narrow SKY) and non selftapping (Nobel Replace - Conical Connection) of the same dimensions.
RESULTS: Results of the experimental study showed a statistically significant correlation between bone density expressed in HU units and primary stability of self-tapping and non-selftapping dental implants expressed in ISQ units in bovine femur bones and self-tapping implants
and pig rib bones. There was no statistically significant correlation between non-self-tapping
dental implants in pig rib bones. Self-tapping and non-self tapping implants did not show statistical significance in primary stability in bones of different quality. In a clinical study, it was
demonstrated that there is a statistically significant strong positive correlation between bone density expressed in HU units measured in CBCT apparatus software and primary stability of dental
implants expressed in ISQ units;
CONCLUSION: The analysis of bone density from CBCT images in the software of the apparatus expressed in HU units can be used to predict the degree of primary stability of self-tapping
and non-self-tapping dental implants in bones of density D1, D2 and self-tapping dental implants
in bones of lower quality D4. The degree of primary stability of non self-tapping dental implants in bones of lower quality D4 cannot be predicted. Higher HU values are associated with higher ISQ values.
Authors Key words
gustina kosti, CBCT, primarna stabilnost, oseointegracija,
dentalni implantati
Authors Key words
bone density, CBCT, primary stability, osseointegration, dental implants
Classification
616.314-089.843-(043.3)
Type
Tekst
Abstract (sr)
UVOD: Oseointegracija predstavlja preduslov uspjeha implantatne terapije. Kvalitet i kvantitet kosti, dizajn implantata i hirurška tehnika ugradnje, su najznačajniji faktori koji utiču na primarnu stabilnost implantata koja predstavlja preduslov oseointegracije.
METODOLOGIJA: U razrešenju postavljenih ciljeva sprovedena je eksperimentalna
studija na materijalu životinjskog porijekla: goveđem femuru i svinjskim rebrima i klinička prospektivna eksperimantalna studija na ljudima, sa nedostatkom jednog zuba u
bočnoj regiji indikovanih za ugradnju implantata. U ovoj studiji su korišćene dvije
vrste imlantata: samourezujući (Bredent-Narrow SKY) i neurezujući (Nobel Replace –
Conical Connection) istih dimenzija.
REZULTATI: Rezultati eksperimentalne studije su pokazali statistički značajnu
povezanost gustine kosti izražene u HU jedinicama i primarne stabilnosti
samourezujućih i neurezujućih dentalnih implantata izražene u ISQ jedinicama u
kostima goveđeg femura i samourezujućih implantata i kostima svinjskog rebra. Nije
bilo statistički značajne povezanosti neurezujućih dentalnih implantata u kostima
svinjskog rebra. Samourezujući i neurezujući implantati nijesu pokazali statistički
značajnost u primarnoj stabilnosti u kostima različitog kvaliteta. U kliničkoj studiji
je dokazano da postoji statistički značajna jaka pozitivna povezanost između gustine
kosti izražene u HU jedinicama izmjerene u softveru CBCT aparata i primarne
stabilnosti dentalnih implantata izraženih u ISQ jedinicama;
ZAKLjUČAK: Analizom gustine koštanog tkiva CBCT sniimka u softveru aparata
izraženom u HU jedinicama može se predvidjeti stepen primarne stabilnosti
samourezujućih i neurezujućih dentalnih implantata u kostima gustine D1, D2 i
samourezujućih dentalnih imlantata u kostima slabijeg kvaliteta gustine D4. Stepen
primarne stabilnosti neurezujućih dentalnih implantata u kostima slabijeg kvaliteta
D4 ne može se predvidjeti. Više vrijednosti HU povezane su sa višim vrednostima ISQ.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.