Title
Uticaj Gz+ ubrzanja na organ vida kod pilota ViPVO na humanoj centrifugi
Creator
Ranđelović, Danijela, 1968-
Copyright date
2019
Object Links
Select license
Autorstvo-Nekomercijalno-Bez prerade 3.0 Srbija (CC BY-NC-ND 3.0)
License description
Dozvoljavate samo preuzimanje i distribuciju dela, ako/dok se pravilno naznačava ime autora, bez ikakvih promena dela i bez prava komercijalnog korišćenja dela. Ova licenca je najstroža CC licenca. Osnovni opis Licence: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/deed.sr_LATN. Sadržaj ugovora u celini: http://creativecommons.org/licenses/by-nc-nd/3.0/rs/legalcode.sr-Latn
Language
Serbian
Cobiss-ID
Inventory ID
D-3242
Theses Type
Doktorska disertacija
description
Datum odbrane: 30.01.2019.
Other responsibilities
mentor
Srećković, Sunčica, 1965-
predsednik komisije
Šarenac-Vulović, Tatjana, 1973-
član komisije
Petrović, Nenad, 1965-
član komisije
Resan, Mirko.
Academic Expertise
Medicinske nauke
University
Univerzitet u Kragujevcu
Faculty
Fakultet medicinskih nauka
Alternative title
The effect of Gz+ acceleration on the organ of vision in pilots of AF and AFD on a human centrifuge
Publisher
Format
98 listova
Abstract (sr)
Uvod: Preko 80% svih informacija tokom letenja kod pilota je vizuelno. U avijaciji su vidne funkcije značajne zbog praćenja signala na instrument tablama kao i znakova okoline. Velike brzine prilikom poletanja, tokom letenja i prilikom sletanja modernih letilica predstavljaju dodatni napor za organ vida. Od samog početka razvoja vazduhoplovstva, funkciji vida se pridaje izuzetan značaj. Zbog velike praktične primene u vazdušnoj borbi, uticaj +Gz ubrzanja na organ vida je veoma važno za istraživanje. Od svih čulnih funkcija kojima čovek raspolaže vid je
najvažniji kako u pogledu bezbednosti letenja tako i za kvalitet izvršavanja letačkih
zadataka. Kod visokog početnog stepena ubrzanja mogu se javiti značajne promene u
vidnim funkcijama. Međutim, važno je održati oštrinu vida usled primene novih
funkcionalnih displeja za brzu orijentaciju pilota, vizuelne konfiguracije reljefa
terena, prikaza oružanih sistema, protivničkih aviona i dodatno usložnjene
orijentacije u prostoru. Neophodno je nastaviti ispitivanja koja će obezbediti
precizne pokazatelje oštrine vida u stanju realnog +Gz ubrzanja i prostorne
dezorijentacije.
Cilj: Cilj istraživanja bio je da se utvrdi da li postoj uticaj na organ vida kod
pilota borbene avijacije i studenata pilota usled izlaganja +Gz ubrzanju u humanoj
centrifugi.
Abstract (en)
Introduction: Over 80 % of all information a pilot receives during the flight is visual. In aviation due to the importance of visual stimulus and environment sings. The high speeds achieved during the take-off, flight, and landing of modern aircraft present limitations for the visual system. The importance of maintaining visual function during these intervals has been
recognized since the earliest stages of aviation development. Because of the great practical importance of air combat, research on visual stress during flight is of great importance receives much attention. Vision is the most important sensory function in terms of both flight safety and the quality performance of flight duties. At high initial rates of acceleration,
significant changes in visual function can occur. However, the importance of maintaining visual acuity is increasing due to the application of novel functional displays for rapid
orientation of the pilot in space, the configuration of the area field, aircraft opponents, and weapon systems. Therefore, it is necessary to continue studies that will provide accurate indicators of visual acuity in the context of real Gz acceleration and spatial disorientation.
Aim: The aim of this study was to demonstrate impact on the visual acuity on aircraft pilots and pilot students during exposure to +Gz acceleration in human centrifuge.
Material and methods: This test was done as a cross section study. The study was conducted on a defined population, 95 examinees aged 21 to 45 years divided into two groups. We examined the prevalence of exposure to positive acceleration, examined the impact of acceleration on the visual functions of these two groups of subjects. The first group were aircraft pilots, which contained 65 pilots and were exposed to acceleration from +5,5Gz to +
7Gz, while other students pilots, where there were 30 students and who were exposed to an acceleration of +5,5Gz. The study was carried out at the Department of Biodynamic of the Aeromedical Institute where human centrifuge was located and was conducted in accordance with the instructions given for each test. We examined the obtained differences in the acuity
of vision at a distance and proximity, stereoscopic vision, color vision and pupil diameter on acceleration rate. The hemodynamic parameters of diastolic and systolic pressure and pulse were measured. Aircraft pilots were tested for a period of three consecutive days because they were exposed to different acceleration values, while pilot students were tested in one day due
to exposure to lower acceleration values. We also observed differences between these two groups of respondents, which is our important indicator of the status of visible functions at the beginning of a professional career and after many years of flight hours.
Authors Key words
vazduhoplovna medicina, piloti, +Gz ubrzanje, vidne funkcije, humana
centrifuga
Authors Key words
aviation medicine, pilots, + Gz acceleration, visual acuity, human centrifuge
Classification
617.7
Subject
Oko - Poremećaj vida - Piloti
Type
Tekst
Abstract (sr)
Uvod: Preko 80% svih informacija tokom letenja kod pilota je vizuelno. U avijaciji su vidne funkcije značajne zbog praćenja signala na instrument tablama kao i znakova okoline. Velike brzine prilikom poletanja, tokom letenja i prilikom sletanja modernih letilica predstavljaju dodatni napor za organ vida. Od samog početka razvoja vazduhoplovstva, funkciji vida se pridaje izuzetan značaj. Zbog velike praktične primene u vazdušnoj borbi, uticaj +Gz ubrzanja na organ vida je veoma važno za istraživanje. Od svih čulnih funkcija kojima čovek raspolaže vid je
najvažniji kako u pogledu bezbednosti letenja tako i za kvalitet izvršavanja letačkih
zadataka. Kod visokog početnog stepena ubrzanja mogu se javiti značajne promene u
vidnim funkcijama. Međutim, važno je održati oštrinu vida usled primene novih
funkcionalnih displeja za brzu orijentaciju pilota, vizuelne konfiguracije reljefa
terena, prikaza oružanih sistema, protivničkih aviona i dodatno usložnjene
orijentacije u prostoru. Neophodno je nastaviti ispitivanja koja će obezbediti
precizne pokazatelje oštrine vida u stanju realnog +Gz ubrzanja i prostorne
dezorijentacije.
Cilj: Cilj istraživanja bio je da se utvrdi da li postoj uticaj na organ vida kod
pilota borbene avijacije i studenata pilota usled izlaganja +Gz ubrzanju u humanoj
centrifugi.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.