Title
Uloga transezofagealne ehokardiografije u planimetrijskoj proceni značajnosti izolovane aortne stenoze
Creator
Prcović, Biljana M., 1963-
Copyright date
2012
Object Links
Select license
Bez licence - direktna primena zakona
License description
Ako ne izaberete neku od licenci, vaše zaštićeno delo može biti korišćeno samo u okviru opštih ograničenja autorskih prava. Na taj način ne dozvoljavate komercijalno ni nekomercijalno korišćenje, naročito reprodukciju, distribuciju, emitovanje, dostupnost i obradu dela. Izbor Creative Commons (CC) licence promoviše diseminaciju vašeg dela. Za više informacija: http://creativecommons.org.rs/licence
Language
Serbian
Cobiss-ID
Inventory ID
D-2568
Theses Type
PhD thesis
description
datum odbrane: 13.12.2012.
Other responsibilities
mentor
Matunović, Radomir. (ths)
član komisije
Petrović, Marina, 1969- (oth, code: 07193)
član komisije
Rafajlovski, Sašo. (oth)
član komisije
Matić, Mihailo, 1949- (oth, code: 00734)
Academic Expertise
Medicinske nauke
University
Univerzitet u Kragujevcu
Faculty
Fakultet medicinskih nauka
Alternative title
The role of transesophageal echocardiography in planimetric assessment of the significance of isolated aortic stenosis
Publisher
Крагујевац,
Format
PDF/A (listova)
description
Umnoženo za odbranu.
Univerzitet u Kragujevcu, Fakultet medicinskih nauka, 20121213, dr medicinskih nauka, ehokardiografija.
Bibliografija: listovi 122-138.
Izvod ; Abstract.
Abstract (sr)
Cilj studije je da se ispita mogućnost primene planimetrijske transezofagealne metode (TEE) upotrebom multipleinske transezofagealne (TEE) sonde za pouzdano utvrđivanje površine ušća aortne valvule (AVA) u aortnoj stenozi (AS). Rotacijom multipleinske sonde dobija se presek površine i mogućnost centriranja pregleda u dugoj osi stenotične valvule i precizan pregled u kratkoj osi bez pokretanja vrha sonde. Tako se može prikazati AVA u preseku i na nivou duge ose.
Rezultati merenja TEE-AVA metodom su poređeni sa podatcima dobijenim invazivnim
merenjem u toku kateterizacije upotrebom Gorlinove formule i podatcima dobijenim
korišćenjem neinvazivne planimetrijske transtorakalne (TTE-AVA) metode upotrebom
kontinuirane jednačine.
AVA je merena planimetrijskom metodom upotrebom multipleinske TEE sonde kod 54
pacijenta (65(36-85) god)sa poznatom kalcifikovanom aortnom stenozom. Ispitivanje je obuhvatilo 25 muškaraca i 29 žena. Kod tri pacijenta gde je AVA bila izrazito smanjena ( ≤ 0,4 cm²), primenom TEE nije bilo moguće egzaktno proceniti AVA i ona je mogla biti određena samo Gorlinovom formulom. Postoji značajna korelacija između TEE-AVA (0.885(0.76) cm²) i podataka dobijenih priemnom Gorlinove formule (0.689(0.58) cm²)(r= 0.402; p<0.01).Postoji značajna korelacija AVA određene Gorlinovom metodom i TTE-AVA (0.689(0.58) cm²) (r= 0.298; p<0.05).
Multiplein planimetrijska TEE metoda je praktična i pouzdana klinička metoda za
procenu značajnosti AS.
Abstract (en)
The aim of the study was to assess if the aortic valve orifice area (AVA) can be precisly assessed
with planimetric transeesophageal (TEE) method using multiplain transesophageal probe in
patients with aortic stenosis (AS).Multiplain probe can be rotated and this gives better
assessment of area and possibility for focusing in t he l ong a xis o f s tenotic a ortic v alve a nd
precise view in the short axis without additional probe movements. This method presents the
aortic valve orifice area and also the view of AVA at the level of long axis.
Data based on planimetric TEE (TEE-AVA) method using continuous equatation were compared
with data obtained by using invasive catheterisation method based on Gorlin’s formula and AVA
measured with transthoracic echocardiography method (TTE-AVA).
The study included 54 patients (65(36-85) ys), 25 man and 29 women with known AS. The AVA
was assessed with with planimetric transeesophageal method using multiplain transesophageal
probe (TEE-AVA). In three patients with severe AS (AVA ≤ 0,4 cm²) it was impossible to use
planimetric TEE, so Gorlin’s formula was used. In our study, strong correlation exists between
TEE-AVA (0.885(0.76) cm²) and AVA assessed with catheterisation and calculated with Gorlin’s
formula (0.689(0.58) cm²) (r= 0.402; p<0.01). Signifficant correlation was found between AVA
obtained by catheterisation and TTE-AVA (0.689(0.58) cm2) (r= 0.298; p<0.05).
Multiplain planimetric TEE method is practical noninvasive method for preoperative AS
assessment.
Authors Key words
Ehokardiografija, transezofagealna
ehokardiografija, aortni zalistak,stenoza
Authors Key words
transezofagealna ehokardiografija
Classification
aortni zalistak
Subject
stenoza
Subject
dijagnoza
Type
monograph
text - theses
Text
Abstract (sr)
Cilj studije je da se ispita mogućnost primene planimetrijske transezofagealne metode (TEE) upotrebom multipleinske transezofagealne (TEE) sonde za pouzdano utvrđivanje površine ušća aortne valvule (AVA) u aortnoj stenozi (AS). Rotacijom multipleinske sonde dobija se presek površine i mogućnost centriranja pregleda u dugoj osi stenotične valvule i precizan pregled u kratkoj osi bez pokretanja vrha sonde. Tako se može prikazati AVA u preseku i na nivou duge ose.
Rezultati merenja TEE-AVA metodom su poređeni sa podatcima dobijenim invazivnim
merenjem u toku kateterizacije upotrebom Gorlinove formule i podatcima dobijenim
korišćenjem neinvazivne planimetrijske transtorakalne (TTE-AVA) metode upotrebom
kontinuirane jednačine.
AVA je merena planimetrijskom metodom upotrebom multipleinske TEE sonde kod 54
pacijenta (65(36-85) god)sa poznatom kalcifikovanom aortnom stenozom. Ispitivanje je obuhvatilo 25 muškaraca i 29 žena. Kod tri pacijenta gde je AVA bila izrazito smanjena ( ≤ 0,4 cm²), primenom TEE nije bilo moguće egzaktno proceniti AVA i ona je mogla biti određena samo Gorlinovom formulom. Postoji značajna korelacija između TEE-AVA (0.885(0.76) cm²) i podataka dobijenih priemnom Gorlinove formule (0.689(0.58) cm²)(r= 0.402; p<0.01).Postoji značajna korelacija AVA određene Gorlinovom metodom i TTE-AVA (0.689(0.58) cm²) (r= 0.298; p<0.05).
Multiplein planimetrijska TEE metoda je praktična i pouzdana klinička metoda za
procenu značajnosti AS.
“Data exchange” service offers individual users metadata transfer in several different formats. Citation formats are offered for transfers in texts as for the transfer into internet pages. Citation formats include permanent links that guarantee access to cited sources. For use are commonly structured metadata schemes : Dublin Core xml and ETUB-MS xml, local adaptation of international ETD-MS scheme intended for use in academic documents.